Water Specialist Control Valve
- Solid state microprocessor with easy access front panel settings
- Four methods to initiate regeneration; meter immediate, meter delayed, time clock delayed or pressure differential
- Fully programmable regeneration cycle sequence (maximum 9)
- Programmable regeneration cycle times
- Days override feature; 1 – 28 days available
- Backwash and brining ability to 21" diameter tanks
- Downflow/upflow regeneration
- Stores system configuration and operation data in nonvolatile memory
- Coin Cell Lithium battery back-up with a 24 hour carry over
- 12-volt output AC Adapter provides safe and easy installation
- Control valve design provides optimum service and backwash rates
- Pre or Post treated water regenerant refill
- Low salt alarm
- Patented one piece expanding seal spacer stack assembly U.S. Patent 6,402,944
- Patented linearly reciprocating piston operation U.S. Patent 6,444,127
- Reliable and proven DC drive
Water Specialist 1” CC Control Specifications
Inlet/Outlet Fittings……………………………………………………………………….. 3⁄4″ to 1.5” NPS
Cycles ………………………………………………………………………………………… up to 9
Valve Material ………………………………………………………………………………. Noryl (1) or equivalent
Regeneration ……………………………………………………………………………….. downflow/upflow
Flow RateS
Service @ 15 psi drop (includes bypass and meter) ……………… 27 gpm
Backwash @ 25 psi drop (includes bypass) …………………………. 27 gpm
Operating Pressures
Minimum/Maximum …………………………………………………………… 20 – 125 psi
Operating Temperatures
Minimum/Maximum …………………………………………………………… 40o – 110o F
Meter
Accuracy ………………………………………………………………………….. ± 5%
Flow Rate Range……………………………………………………………….. 0.25 – 27 gpm
Volume Range …………………………………………………………………… 20 – 1,500,000 gallons
Totalizer……………………………………………………………………………. 1000 – 99,999,000 gallons
Dimensions & WEIGHT
Distributor Pilot…………………………………………………………………. 1.050″ OD Pipe (3⁄4″ NPS)
Drain Line …………………………………………………………………………. 3⁄4″ or 1″ NPT
Brine Line …………………………………………………………………………. 3
/8″ or 1⁄2″ OD Poly Tube
Mounting Base………………………………………………………………….. 2 1⁄2″- 8 NPSM
Height From Top Of Tank……………………………………………………. 7 3
/8″
Weight ……………………………………………………………………………… 4.5 lbs
Electrical Specifications AC Adapter
U.S. International
Supply Voltage ………………………………………………………………….. 120V AC…………. 230V AC
Supply Frequency……………………………………………………………… 60 Hz …………….. 50 Hz
Output Voltage ………………………………………………………………….. 12V AC…………… 12V AC
Output Current…………………………………………………………………..500 mA…………… 500 mA
Tank Applications
Water Softener…………………………………………………………………..6″ – 21″ Diameter
Water Filter(2) ……………………………………………………………………6″ – 21″ Diameter
Cycles of Operation
Choose up to nine regeneration cycles, in any order, with a wide range of available values:
Cycle Range of values
Backwash…………………………………………………………………………. 1 – 120 minutes
Rinse………………………………………………………………………………… 1 – 120 minutes
Pause (service)………………………………………………………………….. 1 – 480 minutes
Brine (co-current)………………………………………………………………. 1 – 180 minutes
Brine (counter-current)……………………………………………………….. 1 – 180 minutes
Refill (softener) ………………………………………………………………….. 0.1 – 200 pounds
Refill (filter) ……………………………………………………………………….. 0.1 – 20.00 gallons
Options: Backwash Filter, Bypass, Weather Cover
Compatible with the following typical concentrations of regenerants or chemicals: Sodium chloride, potassium
chloride, potassium permanganate, sodium bisulfite, chlorine and chloramines